+86 138 0000 0000 sales@zhouneng.top Reply within 12 hours (GMT+8)
Cooling tower manufacturer · Est. 2003

Cooling towers built for continuous duty, not mild weather.

Counterflow, crossflow, closed-circuit and large industrial towers from 5 to 5,000 m³/h. Each unit is thermally selected against your wet-bulb, flow rate and approach — then molded, assembled and tested in our own works before it ships.

20+Years
1,200+Installations
60+Countries
5–5,000m³/h Range
Industrial cooling tower section drawing
✓
CTI STD-201 thermal performance Third-party tested model series

Specified by

  • HVAC CONTRACTORS
  • POWER EPC
  • CHEMICAL PLANTS
  • DATA CENTRES
  • STEEL MILLS
Product range

Six tower families, one selection standard

From a single rooftop unit to a field-erected industrial tower — same thermal calculations, same material traceability, same after-sales file.

Most specified FRP round counterflow cooling tower

FRP Round Counterflow Tower

Rotomolded fiberglass shell, low noise fan, ideal for rooftops and tight plant rooms.

5–800 m³/hFlow rate
≤ 65 dB(A)Sound
View details →
Square crossflow cooling tower

Square Crossflow Tower

Modular FRP panels, easy site assembly, generous access for fill cleaning and inspection.

50–1,500 m³/hFlow rate
3–5 °CApproach
View details →
Closed circuit cooling tower

Closed Circuit Tower

Sealed coil loop keeps process water clean — for chillers, furnaces and heat exchangers.

30–1,200 m³/hFlow rate
Zero driftProcess side
View details →
Open cooling tower

Open Cooling Tower

High-efficiency film fill and low-pressure spray nozzles for general industrial cooling.

100–3,000 m³/hFlow rate
≥ 45 %Fill efficiency
View details →
Large industrial hyperbolic cooling tower

Large Industrial Tower

Field-erected concrete and steel structures for power stations and heavy process plants.

2,000–5,000 m³/hFlow rate
Field builtErection
View details →
Service Cooling tower spare parts and retrofit

Parts & Retrofit

Replacement fill, drift eliminators, fans, gearboxes and full thermal upgrades for old towers.

15 yearsSpares support
+30 %Typical capacity gain
View details →
Why ZHOUNENG

Engineering first, catalogue second

Most tower failures are selection errors, not manufacturing errors. We start with your duty point and work backwards.

01

Thermal selection, not guesswork

Every quotation carries a calculation sheet: wet-bulb, range, approach, flow and fan power — signed by an engineer.

02

In-house FRP molding

We mold our own shells and basins. No outsourced panels, no mismatched resin batches, no waiting on a third party.

03

Tested before it ships

Hydrostatic leak test at 1.5× design pressure, fan vibration check, and a full run-in on every assembled unit.

04

Spares for 15 years

Fill, nozzles, drift eliminators and drive components stay available long after the warranty window closes.

1,200+Towers delivered
60+Export countries
18 moStandard warranty
99.2%On-time shipment
Applications

Where our towers run

Six industries, six different duty profiles. Selection rules change with them — ours are built around the application, not a single catalogue page.

HVAC & District CoolingChiller condenser water
Power GenerationSteam turbine cooling
Chemical & PetrochemicalProcess water cooling
Steel & MetallurgyFurnace & rolling mill
Food & BeverageHygienic process loops
Data CentresHigh-density heat rejection
How we work

From duty point to commissioning

Four stages, one engineer responsible for your file from first email to final handover.

Site data & consultation

You send flow, inlet/outlet temperature, wet-bulb, altitude and layout constraints. We flag anything that will hurt performance.

Thermal selection

Selection report with tower size, fan power, pressure drop, water volume and a dimensioned general arrangement drawing.

Manufacturing & FAT

Production schedule with weekly photo reports. Factory acceptance test with your inspector welcome on site.

Shipment & commissioning

Export packing, container loading plan, and remote or on-site commissioning support for the first start-up.

ISO 9001 Quality system CTI STD-201 CE Machinery ASME Section VIII (coils)
Quality control

Every unit leaves with a test file

Six inspection hold points are signed off between raw material intake and container loading. You get the complete record — not a certificate that says “trust us”.

  • Resin and glass batch traceability for every molded shell
  • Hydrostatic test at 1.5× design pressure, 30-minute hold
  • Fan balance and vibration check under load
  • Fill and drift eliminator sampling per ASTM test methods
  • Dimensional check against approved GA drawing
  • Pre-shipment photo report with serial numbers

Tell us your duty point.

Send flow rate, temperatures and site conditions — we’ll return a selection and a budget price within two working days.

Get a Selection